Scholarly Works
Research Output
Recent Publications
Transfer learning with class activation maps in compositions driving plaque classification in carotid ultrasound
Publishing year: 2025
Journal article
Frontiers in Digital Health, 2025, Volume 7
Scopus
Introduction: Carotid B-mode ultrasound (U/S) imaging provides more than the degree of stenosis in stroke risk assessment. Plaque morphology and texture have been extensively investigated in U/S images, revealing plaque components, such as juxtaluminal black areas close to lumen (JBAs), whose size is linearly related to the risk of stroke. Convolutional neural networks (CNNs) have joined the battle for the identification of high-risk plaques, although the ways they perceive asymptomatic (ASY) and symptomatic (SY) plaque features need further investigation. In this study, the objective was to assess whether class activations maps (CAMs) can reveal which U/S grayscale-(GS)-based plaque compositions (lipid cores, fibrous content, collagen, and/or calcified areas) influence the model's understanding of the ASY and SY cases. Methods: We used Xception via transfer learning, as a base for feature extraction (all layers frozen), whose output we fed into a new dense layer, followed by a new classification layer, which we trained with standardized B-mode U/S longitudinal plaque images. From a total of 236 images (118 ASY and 118 SY), we used 168 in training (84 ASY and 84 SY), 22 in internal validation (11 ASY and 11 SY), and 46 in testing (23 ASY and 23 SY). Results: In testing, the model reached an accuracy, sensitivity, specificity, and area under the curve at 80.4%, 82.6%, 78.3%, and 0.80, respectively. Precision and the F1 score were found at 81.8% and 80.0%, and 79.2% and 80.9%,...
Position paper: Artificial intelligence in medical image analysis: Advances, clinical translation, and emerging frontiers
Publishing year: 2025
Journal article
IEEE Journal of Biomedical and Health Informatics, 2025, 2025
Google Scholar
Over the past five years, artificial intelligence (AI) has introduced new models and methods for addressing the challenges associated with the broader adoption of AI models and systems in medicine. This paper reviews recent advances in AI for medical image and video analysis, outlines emerging paradigms, highlights pathways for successful clinical translation, and provides recommendations for future work. Hybrid Convolutional Neural Network (CNN) Transformer architectures now deliver state-of-the-art results in segmentation, classification, reconstruction, synthesis, and registration. Foundation and generative AI models enable the use of transfer learning to smaller datasets with limited ground truth. Federated learning supports privacy-preserving collaboration across institutions. Explainable and trustworthy AI approaches have become essential to foster clinician trust, ensure regulatory compliance, and …
Identifying Carotid Plaque Compositions Exhibiting Discordant Motion in B-Mode Ultrasound Videos
Publishing year: 2025
Conference paper
Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society EMBS, 2025
Scopus
This study aimed to analyze 2D B-mode longitudinal carotid ultrasound videos to identify and characterize the motion of plaque compositions. Understanding these motion patterns in both asymptomatic (AS) and symptomatic (SY) cases may provide valuable insights into plaque instability and its potential role in rupture and ischemic stroke. We included 20 carotid ultrasound videos (10 AS and 10 SY patient videos). First, a previously trained and evaluated Deep Learning model segmented the whole plaque region of interest (ROIs), per video frame. Based on a heuristic computational approach, we contoured each ROI into 6 colors (6 grayscale, GS intensity ranges), depicting different histological compositions (e.g., calcified areas, areas with fibrous content and/or collagen, and lipid cores). We estimated motion of the whole plaque and that of each composition, across 3 systoles per video, calculating the Maximum Angular Spread (MAXFW) and the maximum median motion magnitude. The GS≤25 areas in highly-discordant AS and SY plaques exhibited the largest MAXFW (moderate-discordant motion), compared to other compositions. The MAXFW of the GS≤25 in concordant AS plaques, although higher compared to others, showed a concordant motion. Overall, the angular and the motion spread both showed a continuous increase from the brighter to the darkest areas in the highly-discordant AS and SY plaques. These findings might reflect a key involvement of the echolucent plaque areas in the development of...
Explainable artificial intelligence in the prediction of high-risk asymptomatic carotid plaques based on ultrasonic image features
Publishing year: 2025
Journal article
International Angiology, 2025, Volume 44, Issue 4
Scopus
Pages 291-300
Background: The addition of ultrasonic plaque texture features to clinical features in patients with asymptomatic internal carotid artery stenosis (ACS) improved the ability of a Support Vector Machine (SVM) model to identify plaques that are likely to produce stroke. However, SVM like manyArtificial Intelligence (AI) black-box models lack transparency, limiting their adoption in critical settings. Explainable AI (XAI) techniques offer potential solutions by making model decision more interpretable. This study investigates whether incorporating XAI techniques can improve interpretability without significantly compromising predictive accuracy in stroke risk assessment. Methods: We developed an Argumentation-based Explainable Machine Learning (ArgEML) methodology and framework for explainable machine learning predictions via argumentation. We used this framework to learn explainable argumentation theories from a real-life dataset of patients with asymptomatic carotid stenosis. We assessed the performance of these theories using standard machine learning (ML) metrics, while interpretability was evaluated through model transparency and quality of explanations. Results: Results indicate that the ArgEML models maintain high predictive accuracy while significantly improving the interpretability of the predictions. Moreover, undecided predictions are addressed as dilemmas which still offer valuable information through the explanations of the different prediction capabilities. Conclus...
Diaphragmatic Motion Analysis in Neonates Using Ultrasound Simulated Videos
Publishing year: 2025
Conference paper
IFIP Advances in Information and Communication Technology, 2025, Volume 758 IFIPAICT
Scopus
Pages 98-111
Ultrasound analysis of the diaphragm can provide valuable insights into diaphragmatic function in neonates, potentially enabling physicians to identify disease-related abnormalities. We propose and evaluate an integrated semi-automated video analysis system for the accurate diaphragmatic motion analysis in neonates. In order to enhance the clinical learning outcome and precisely assess the suggested system, we employed 20 simulated ultrasound videos of the diaphragm that were produced using characteristics of typical neonate’s diaphragmatic motion. To evaluate the proposed system, manual (performed by a doctor) vs automated measurements were extracted and diaphragmatic excursion (DE), inspiration time (Tinsp), total breathing time (Ttot), diaphragmatic curve slope (DSP), and relaxation rate (RR) were measured. The following manual (–/) vs semi-automated (/–), (median ± IQR) measurements were computed for all simulated videos; The correlation coefficient (ρ, p-value) are also given showing the correlation of the parameters measured by the doctor vs the proposed system: (i) DE: (3.66 ± 0.11)/3.71 ± 0.24 mm (ρ = 0.97, p = 0.002), (ii) Tinsp: (0.55 ± 0.19)/(0.57 ± 0.16) sec (ρ = 0.91, p = 0.002), (iii) Ttot: (1.31 ± 0.19)/(1.31 ± 0.18) sec (ρ = 0.90, p = 0.005), (iv) DSC: 6.69 ± 2.73/6.58 ± 2.31 mm/sec (ρ = 0.79, p = 0.003), (v) RR: 4.88 ± 0.15/5.08 ± 0.57 mm/sec (ρ = 0.89, p = 0.001). This is the first study reported in the literature that utilizes a semi-automated integrated mo...
Brain Magnetic Resonance Imaging Segmentation System in MS with Deep Neural Networks
Publishing year: 2025
Conference paper
Lecture Notes of the Institute for Computer Sciences Social Informatics and Telecommunications Engineering Lnicst, 2025, Volume 611 LNICST
Scopus
Pages 325-339
Multiple Sclerosis (MS) is a chronic autoimmune disease that affects the central nervous system. Nerves are covered by a layer called myelin, which is responsible for protecting and maintaining their functionality. In the case of MS, the myelin becomes damaged, resulting in the nerves functioning unpredictably. MS is a disease characterized by relapses, which can cause permanent and irreversible damage to the patient's mobility, vision, and sensations, unless appropriate medical treatment is administered in time. This highlights the importance of the early detection of the presence or differentiation of MS using computer assisted diagnosis (CAD) systems. This study proposes an automatic segmentation approach of MS damaged regions using deep neural networks that can be integrated with any 3rd party CAD system. The data utilized comprised of a total of 1838 T2-type Magnetic Resonance Imaging (MRI) images collected from a cohort of 38 patients who underwent imaging at two distinct time points. Each MRI image was accompanied by meta-data, detailing the specific locations of the observed damage attributed to MS. The experimental setup investigated and optimized a comprehensive combination of different data preprocessing and augmentation steps, using several variations of the U-Net convolutional neural network (CNN), like U-Net++, Attention U-Net, ResUNet-a and TransUNet. The proposed methods achieved a segmentation accuracy of 0.70 based on the Dice Similarity Coefficient (DSC), a...
198
Unique publications
44.4%
Open access (88 publications; 59 without information)
55.1%
With other institutions (109 publications; 74 without information)
H-Index Reports
| Index type | Scopus | Google Scholar | Web of Science |
|---|---|---|---|
| H-index | 26 | 31 | 1 |
| H5-index | 8 | 11 | 1 |
| H10-index | 10 | 14 | 1 |
Publications per year and source
No description yet.
- Faculty
- Faculty of Engineering and Technology
- Department
- Department of Electrical Engineering, Computer Engineering and Informatics
- Title
- Dr