ΕΛ EN
Home | People | Kapnisis, Konstantinos
64
Scholarly Works
30%
OA Ratio
38%
Collaborative Ratio
Scholar

Kapnisis, Konstantinos

Special Teaching Staff

Department of Mechanical Engineering and Materials Science and Engineering

15
H-index (Scopus)
792
Scholar Citations

Scholarly Works

Research Output

Recent Publications

In Vitro Evaluation of the Effect of Stenting on Hematological, Hemorheological and Hemodynamic Parameters, in Various Stent Configurations and Flow Conditions: D. Kokkinidou …

D Kokkinidou, K Kapnisis, M Chrysostomou, C Shammas, A Anayiotos, ...
Publishing year: 2025
Journal article
Cardiovascular Engineering and Technology 16 (5), 525-536, 2025, 2025
Google Scholar
Pages 1-12
Purpose Percutaneous coronary intervention is used extensively for the restoration of blood flow in diseased arteries. The influence of stent implantation on the physiology and flow of blood is an important and still not fully understood issue. The current work evaluated possible stent-induced changes in hematological, hemorheological and hemodynamic parameters. Methods Experiments were performed for blood flow in single and overlapping stent configurations, in both straight and curved tube geometries, in order to reproduce various stented coronary artery morphologies. Two different flow regimes were utilized to reflect a range of physiological and more intense flow conditions. Blood samples were obtained from a healthy human population and commercially available stents were inserted in clear perfluoroalkoxy alkane tubing, connected to a syringe/syringe-pump/pressure-sensor setup. Hematological …

In Vitro Evaluation of the Effect of Stenting on Hematological, Hemorheological and Hemodynamic Parameters, in Various Stent Configurations and Flow Conditions

Anayiotos, Andreas, Chrysostomou, M., Kaliviotis, Efstathios, Kapnisis, Konstantinos, Kokkinidou, Despoina, Shammas, Christos
Publishing year: 2025
Journal article
Cardiovascular Engineering and Technology, 2025, Volume 16, Issue 5
Repository
Pages 525-536
Percutaneous coronary intervention is used extensively for the restoration of blood flow in diseased arteries. The influence of stent implantation on the physiology and flow of blood is an important and still not fully understood issue. The current work evaluated possible stent-induced changes in hematological, hemorheological and hemodynamic parameters.

In Vivo Biocompatibility And Tissue Response Of Poly(glycerol Sebacate Urethane) Scaffolds Intended For Tendon Repair

Publishing year: 2024
Journal article
2024, Volume 30, Issue 15-16
Web of Science
Pages S455-S455

Analytical Solutions of PBTK Models for Evaluating the Impact of Surface Diffusion Characteristics on the Leaching Profile of Implant Bioproducts

Anayiotos, Andreas, Giakoumi, Matheos, Kapnisis, Konstantinos, Stephanou, Pavlos S.
Publishing year: 2024
Journal article
Mathematical and Computational Applications, 2024, Volume 29, Issue 6
Repository
Toxicokinetic or pharmacokinetic models, physiologically based or not, offer a unique avenue to understand the transport of toxins or pharmaceuticals in living organisms. The availability of analytical solutions to such models offers the means to engage in a plethora of applications. In the present work, we provide the framework to solve analytically such models using the matrix exponential, and we then apply this method to derive an explicit solution to four-to-five-compartment physiologically based toxicokinetic (PBTK) models considering a single- and an infinite-exponential expression for the amount of mass released from an implantable device. We also offer the conditions that need to be met for analytical solutions to be obtained when the kinetic rates are time-dependent functions. Our analysis compares the computation time between analytical and numerical solutions and characterizes the dependency of the maximum substance mass value and the time it occurs in the various tissue compartments from the material surface diffusion characteristics. Our analytical solutions, which have several advantages over the solutions obtained using numerical solvers, can be incorporated into in silico tools and provide valuable information for human health risk assessment.

A Predictive Toxicokinetic Model for Nickel Leaching from Vascular Stents

Anayiotos, Andreas, Giakoumi, Matheos, Kapnisis, Konstantinos, Kokkinidou, Despoina, Papastefanou, Chara, Stephanou, Pavlos S.
Publishing year: 2024
Journal article
ACS Biomaterials Science and Engineering, 2024, Volume 10, Issue 4
Repository
Pages 2534-2551
In vitro testing methods offer valuable insights into the corrosion vulnerability of metal implants and enable prompt comparison between devices. However, they fall short in predicting the extent of leaching and the biodistribution of implant byproducts under in vivo conditions. Physiologically based toxicokinetic (PBTK) models are capable of quantitatively establishing such correlations and therefore provide a powerful tool in advancing nonclinical methods to test medical implants and assess patient exposure to implant debris. In this study, we present a multicompartment PBTK model and a simulation engine for toxicological risk assessment of vascular stents. The mathematical model consists of a detailed set of constitutive equations that describe the transfer of nickel ions from the device to peri-implant tissue and circulation and the nickel mass exchange between blood and the various tissues/organs and excreta. Model parameterization was performed using (1) in-house-produced data from immersion testing to compute the device-specific diffusion parameters and (2) full-scale animal in situ implantation studies to extract the mammalian-specific biokinetic functions that characterize the time-dependent biodistribution of the released ions. The PBTK model was put to the test using a simulation engine to estimate the concentration-time profiles, along with confidence intervals through probabilistic Monte Carlo, of nickel ions leaching from the implanted devices and determine if p...

On the development of physiologically based toxicokinetic (PBTK) models for cardiovascular implants

Anayiotos, Andreas, Giakoumi, Matheos, Kapnisis, Konstantinos, Stephanou, Pavlos S.
Publishing year: 2023
Journal article
Regulatory toxicology and pharmacology : RTP, 2023, Volume 144
Repository
Local and systemic contamination caused by metal ions leaching from medical device materials is a significant and continuing health problem. The increasing need for verification and validation, and the imposition of stringent government regulations to ensure that the products comply with the quality, safety, and performance standards, have led regulatory bodies worldwide to strongly recommend the use of modeling and simulation tools to support medical device submissions. A previously published physiologically based toxicokinetic (PBTK) model, is here expanded and enriched by an additional separate tissue compartment to better resemble normal physiology and by the introduction of time-dependent functions to describe all biokinetic parameters. The new model is exercised in conjunction with state-of-the-art probabilistic, Monte Carlo methodology to calculate the predictions' confidence intervals and incorporate variability associated with toxicological biodistribution studies. The quantitative consistency of the model-derived predictions is validated against reported data following the implantation of nickel-containing cardiovascular devices in humans and minipigs. Finally, a new methodology for compartmental toxicological risk assessment is presented that can be used for forward or reverse dosimetry. Our work is aimed at providing a computational tool to optimize the device design characteristics and safeguard that the substances released do not exceed permissible exposure limi...

64
Unique publications
29.7%
Open access (19 publications; 31 without information)
37.5%
With other institutions (24 publications; 32 without information)

H-Index Reports

Index type Scopus Google Scholar Web of Science
H-index 15 15 1
H5-index 6 8 1
H10-index 11 12 1

Publications per year and source

No description yet.
Faculty
Faculty of Engineering and Technology
Department
Department of Mechanical Engineering and Materials Science and Engineering
Title
Special Teaching Staff