Scholarly Works
Research Output
Recent Publications
Experimental investigation of nonplanar beam-slab to shear wall connections under cyclic loading (ERIES-NOBLE project)
Publishing year: 2026
Conference paper
Fib Symposium, 2026
Scopus
Pages 61119-6128
It is very common in existing or newly designed RC buildings that beams are connected to shear walls (individual or core-type) in the out-of-plane (i.e., weak) direction. Little attention has been paid on the seismic performance of this type of connections with very limited experimental research up to date. Previous experimental tests on RC joints mainly focused on beam-column, coplanar beam-wall, and slab-column joints. Furthermore, Eurocode 8, as well as other international seismic codes, are silent regarding the design and detailing of these joints. In the framework of the EU-funded project ERIES “Engineering Research Infrastructures for European Synergies 2022-2026”, ERIES-NOBLE project investigates the seismic performance of nonplanar beam-slab to wall interior joints through three full-scale tests. The tests were conducted at the Structures Laboratory (STRULAB) of the University of Patras (Greece), where the specimens were tested under quasi-static cyclic loading in displacement control. The specimens comprise a segment of a shear wall (section 1500x250mm) starting from the mid-height of a floor up to the mid-height of the next floor (points of contraflexure for bending of the wall in its weak direction), with a total specimen height of 3.05m. The beams (section 250x450mm) are also included up to their point of contraflexure (mid-length of the beam), with a total specimen length of 5.40m. Slab has a thickness of 150mm. Steel reinforcement and detailing differs in each s...
Experimental Dataset From Full‐Scale Test Results on Nonplanar Beam–Slab to Shear Wall Connections Under Cyclic Loading (ERIES‐NOBLE Project)
Publishing year: 2026
Journal article
Earthquake Spectra, 2026
ORCID
Predicting the Tensile Behavior of Textile Reinforced Mortar composites: A Comparative Study of Established Simplified Models
Publishing year: 2025
Conference paper
Fib Symposium, 2025
Scopus
Pages 3740-3751
The recent evolution of using Textile Reinforced Mortar (TRM) as a sustainable and compatible solution for retrofitting existing masonry and RC structures, requires the development of simplified models able to predict the behavior of this composite material. This is essential for designing TRM strengthening measures effectively and further for the development of preliminary design guidelines for such applications. This paper presents the comparison between two simplified models used for predicting the tensile behavior of TRM: Filippou et al. [1] and Rampini et al [2] model. This comparative study showed that both models proved accurate for predicting the stress-strain relationship of TRM under tensile loading, but both models have some limitations and weaknesses. At the end, each model's limitations, as well as the differences of the two models are discussed.
Integrated Approach of Retrofitting an Existing Residential Building to a Nearly Zero Energy Building with Simultaneous Seismic Upgrading
Publishing year: 2024
Journal article
Open Construction and Building Technology Journal, 2024, Volume 18, Issue 1
Repository
Introduction: The current study's goal is to apply an integrated approach of retrofitting a typical building in Cyprus that was designed and constructed for the refugee settlements in the period 1975-1985. The existing building is retrofitted to a nearly zero-energy building. Methods: This typical type of building examined represents approximately 15,347 houses and stands for 3.57% of households in Cyprus. This percentage is considered significant with regards to energy consumption, as this type of structure has an estimated energy consumption of 1000 kWh/m2/y and CO2 emissions of 293.74kg CO2/m2/y. This corresponds to 0.293 Mt CO2/y, which stands for 4.18% of total CO2 emissions in Cyprus for 2011, based on the latest IEA (International Energy Agency) data. An integrated approach is followed for the retrofitting of the existing building, which involves both energy and structural upgrades, taking into account the earthquake resistance upgrade. Since Cyprus is in a highly seismic region, an important factor in this approach is the ability of the structure to survive a strong earthquake during its remaining lifetime, according to the design criteria. The study presents and discusses three possible coalitions with multiple scenarios of approaching the upgrade of the existing building. In each coalition, various criteria and implementation actions are considered based on the energy consumption, the CO2 footprint, and the seismic resistance. Results: The study also investigates wh...
Corrigendum to: Integrated Approach of Retrofitting an Existing Residential Building to a Nearly Zero Energy Building with Simultaneous Seismic Upgrading (Open Construction & Building Technology Journal, (2024) 18, 10.2174/0118748368265332231220060905)
Publishing year: 2024
Journal article
Open Construction and Building Technology Journal, 2024, Volume 18
Scopus
In the online version of the article, a change was made in the author’s list of the article titled “Integrated Approach of Retrofitting an Existing Residential Building to a Nearly Zero Energy Building with Simultaneous Seismic Upgrading,” which has been updated in “The Open Construction & Building Technology Journal,” 2024; 18: e18748368265332 [1]. The original article can be found online at: https://openconstructionbuildingtechnologyjournal.com/V OLUME/18/ELOCATOR/e18748368265332/ Original: George Pamboris1,*, Chrysostomou Christis Z.1, Soteris A. Kalogirou2 and Christodoulides Paul31 Department of Civil Engineering and Geomatics, Cyprus University of Technology, Limassol 3603, Cyprus2 Department of Mechanical Engineering and Materials Science and Engineering, Cyprus University of Technology, Limassol 3603, Cyprus3 Faculty of Engineering and Technology, Cyprus University of Technology, Limassol 3603, Cyprus Corrected: George Pamboris1,*, Christis Z. Chrysostomou1, Soteris A. Kalogirou2 and Paul Christodoulides31 Department of Civil Engineering and Geomatics, Cyprus University of Technology, Limassol 3603, Cyprus2 Department of Mechanical Engineering and Materials Science and Engineering, Cyprus University of Technology, Limassol 3603, Cyprus3 Faculty of Engineering and Technology, Cyprus University of Technology, Limassol 3603, Cyprus.
ASSESSMENT OF INTEGRATED SEISMIC AND ENERGY UPGRADING OF BUILDINGS THROUGH FULL-SCALE TESTING
Publishing year: 2024
Book chapter
World Conference on Earthquake Engineering Proceedings, 2024, Volume 2024
Scopus
The European building stock is vulnerable to earthquake actions and responsible for 40% of the total energy consumption. Thus, there is an urgent socio-economic and environmental need in Europe for sustainable and effective solutions. Towards this direction, an experimental campaign in the framework of the SupERB project was carried out to investigate the efficiency of using integrated seismic and energy upgrading systems. The integrated approach is based on the use of Textile Reinforced mortar (TRM) overlays combined either with traditional thermal insulation (extruded polystyrene, XPS) or with thermally efficient mortar incorporating phase change material (PCMs). The proposed integrated approach can be applied on the exterior face of the structure, so as to provide confinement to the building, and minimum disturbance to its inhabitants. In-plane lateral load testing of full-scale one-story one-bay masonry infilled RC frames and load-bearing masonry walls retrofitted with different schemes of TRM combined with thermal insulation materials was carried out in the framework of the SupERB project. In that project a series of tests for examining the energy performance of various retrofitting solutions were also carried out, along with the formulation of a methodology for the selection of the best solution for integrated seismic and energy upgrading for a given structure. In this paper, the structural performance of masonry-infilled RC frames retrofitted with different schemes of...
101
Unique publications
28.7%
Open access (29 publications; 22 without information)
45.5%
With other institutions (46 publications; 25 without information)
H-Index Reports
| Index type | Scopus | Google Scholar | Web of Science |
|---|---|---|---|
| H-index | 20 | 23 | 1 |
| H5-index | 6 | 4 | 1 |
| H10-index | 9 | 7 | 1 |
Publications per year and source
No description yet.
- Faculty
- Faculty of Engineering and Technology
- Department
- Department of Civil Engineering and Geomatics
- Title
- Professor