ΕΛ EN
Home | People | Argyrou, Maria C.
26
Scholarly Works
27%
OA Ratio
50%
Collaborative Ratio
Scholar

Argyrou, Maria C.

Department of Electrical Engineering, Computer Engineering and Informatics

10
H-index (Scopus)
1411
Scholar Citations

Scholarly Works

Research Output

Recent Publications

Group A Streptococcal Invasive Infections Among Children in Cyprus

Publishing year: 2025
Journal article
2025, Volume 13, Issue 8
Web of Science

Power cable simulation of failure through temperature monitoring of optical fibres with a state-of-the-art distributed sensing instrument

Agathocleous, Michalis, Argyrou, Maria C., Caucheteur, Christophe, Chatzis, Sotirios P., Dionysiou, Antreas, Ioannou, Andreas, Kalli, Kyriacos, Karaulanov, Rumen, Kouzoupou, Charalambos, Marchesini, Pierpaolo, Metaxas, A...
Publishing year: 2023
Conference paper
Proceedings of SPIE - The International Society for Optical Engineering, 2023, Volume 12643
Repository
In this work we utilize multimode optical fibers for the detection of simulated errors or failures in underground power cables. It is known that in cases of failure the underground transmission cables overheat locally, they become a hot-spot, and it is extremely difficult to detect and locate the problem. The proposed methodology is as follows, having an underground electric cable we simulate various temperature profiles whilst the optical fiber was placed in selected distances away from our simulated fault to examine the detection performance of our fiber. In this way we aim to stabilize the operation of the underground cable damage detection system that is placed by the Electricity Authority of Cyprus. The EAC has certain locations where the existing single-mode optical fibres are collocated with the underground power cables, although relative spacing may not be constant. Our data will give an indication of how important is uniform spacing between power and optical cables. We examine if any change in the temperature of the power cable is also reflected in the optical fibre cable. The real-time and continuous monitoring of the temperature of the optical cables through the distributed sensing systems may help identifying abnormal cable behaviour (hot spots) and possible future network failures in the power network.

Equipment Parameter Investigation for a Proposed Power Conductor Hot Spot Identification system

Argyrou, Maria C., Ioannou, Andreas, Kalli, Kyriacos, Komodromos, Michael, Polycarpou, Alexis
Publishing year: 2023
Conference paper
Proceedings of 2023 10th International Conference on Modern Power Systems, 2023
Repository
Reliability, efficiency and continuity of power energy supplied is an area which receives increasing attention as the main infrastructure of power transmission and distribution systems in many countries is ageing. Hot spot related cable failures and power interruptions have a big financial impact on the power provider. The operational parameters of a method to identify in real time hot spots on cables is investigated in this paper, which can result to timely fault prevention. This can be achieved through exploiting the optical sensing capabilities of the existing optical fibre on-grid network. The resulting parameters aim to be advantageous for the system as they increase accuracy and will enable the Remote, automated, continuous, and real time monitoring of the grid infrastructure integrity.

EAC power distribution line cable monitoring using state-of-the-art distributed sensing instruments

Agathocleous, Michalis, Argyrou, Maria C., Baldini, Francesco, Dionysiou, Antreas, Homola, Jiri, Ioannou, Andreas, Kalli, Kyriacos, Karaulanov, Rumen, Komodromos, Michael, Kouzoupou, Charalambos, Lieberman, Robert A., Ma...
Publishing year: 2023
Conference paper
Proceedings of SPIE - The International Society for Optical Engineering, 2023, Volume 12572
Repository
We examine the use of state-of-the-art distributed sensing systems to extract temperature information from the optical fibre infrastructure already of the Electricity Authority of Cyprus power distribution network (~25-year old installation); as a means of optical fibre distributed sensing in the underground cables. The optical fibres are collocated with existing power distribution cables, for the purpose of power line monitoring cable joints that are prone to failure, along with general monitoring for unusual behaviour and potential cable fault conditions. Detection is achieved using DTS: Distributed Temperature Sensors (Silixa Ltd) that use RAMAN-based measurements in combination with BOTDR (Brillouin Optical Time-domain Reflectometry) for high-precision temperature detection. We examine the correlation between the temperature of the power cable with the power consumption provided by the EAC and the weather conditions. Furthermore, our data will give an indication of how important is uniform spacing between power and optical cables. The real-time and continuous monitoring of the temperature of the optical cables through the distributed sensing systems may help identifying abnormal cable behavior (hot spots) and possible future network failures in the power network.

Application of machine learning on optical fibre distributed sensing for power line applications

Argyrou, Maria C., Baldini, Francesco, Chatzis, Sotirios P., Homola, Jiri, Ioannou, Andreas, Kalli, Kyriacos, Kouzoupou, Charalambos, Lieberman, Robert A., Panaretou, Georgios
Publishing year: 2023
Conference paper
Proceedings of SPIE - The International Society for Optical Engineering, 2023
Repository
We present a study on the application of machine learning to optical fibre distributed sensing, with data recovered using a state-of-the-art, commercial BOTDR distributed sensing system; temperature information was extracted from the power line distribution networks that are part of the Electricity Authority of Cyprus. A machine learning approach was implemented for the prediction task of finding points of abnormal behaviour, mimicking the power cable joints that are prone to failure, along with general monitoring for unusual behaviour and potential cable fault conditions; the task is a binary classification one. Labels “0/1” were assigned to the BOTDR measurements, with “1” corresponding to data points in space and time for which the signal showcased a problematic scenario, such as that recorded by optical fibres that are collocated with power cables where the fibre’s temperature measurement increases to dangerously high values, and conversely “0” for all other scenarios. The algorithm’s base is a variation of the state-of-the-art transformer architecture, which depends solely on attention mechanisms. The field data recovered show the potential of the algorithm to predict spatiotemporally problematic points, using the temperature measurements of the collocated fibre.

A Method of Fitting BOTDA Data for the Estimation of the Brillouin Frequency Shift

Argyrou, Maria C., Baldini, Francesco, Homola, Jiri, Ioannou, Andreas, Kalli, Kyriacos, Komodromos, Michael, Lieberman, Robert A., Polycarpou, Alexis
Publishing year: 2023
Conference paper
Proceedings of SPIE - The International Society for Optical Engineering, 2023, Volume 12572
Repository
A Brillouin Optical Time-Domain Analysis (BOTDA) Lorentzian data fitting method to estimate the Brillouin Frequency Shift (BFS) at successive locations along the length of the sensing optical fiber is proposed. The data used to test the method is obtained from an experimental setup built to conduct temperature and strain measurements. Before Lorentzian fitting the noisy data is averaged and filtered. The proposed method attempts to lower computational complexity in determining the BFS at each location by using the resulting parameters of a completed Brillouin gain spectrum (BGS) curve-fitting as initial set of parameters for the next location BGS fitting. Completion of the Lorentzian fittings using the Levenberg-Marquardt nonlinear curve fitting algorithm is achieved in a smaller number of iterations, improving the performance in obtaining the BFS.

26
Unique publications
26.9%
Open access (7 publications; 2 without information)
50%
With other institutions (13 publications; 3 without information)

H-Index Reports

Index type Scopus Google Scholar Web of Science
H-index 10 11 0
H5-index 3 4 0
H10-index 10 11 0

Publications per year and source

No description yet.
Faculty
Faculty of Engineering and Technology
Department
Department of Electrical Engineering, Computer Engineering and Informatics