Scholarly Works
Research Output
Recent Publications
Evaluation of the optimum insulation thickness of building external walls and roof based on human thermal comfort criterion
Publishing year: 2025
Journal article
Renewable Energy, 2025, Volume 247
Scopus
The need to save energy in the buildings is a key priority, as buildings consume the largest share of energy and have the greatest potential for energy savings. A large amount of this energy consumed, is used for heating and cooling of the buildings. One of the measures that contributes substantially to energy savings in housing is the appropriate thermal insulation material of the exterior walls and the building envelope in general. However, determining the optimal insulation thickness (OpIT) based on economic indicators, such as net present value or pay-back period, has high degree of uncertainty due to the impossibility of accurately predicting future energy prices. In addition, considering one set-point temperature for the winter and another for the summer season does not ensure thermal comfort inside the dwelling. In the present study, a criterion based on the human thermal comfort index was used, to determine the optimal thickness of the insulation of the external walls and roof. Thus, a dynamic thermal simulation of a typical house, using hourly weather data of Athens-Greece and Larnaca-Cyprus was performed, and an optimization algorithm was used to determine the optimal insulation thickness for the roof and for each wall individually. In addition, for the calculation of the outdoor heat transfer coefficient, the wind speed and direction have been taken into account. For the considered typical house and the corresponding climatic data, the OpIT was found to range from...
Applications and New Technologies Pertaining to Waste Heat Recovery: A Vision Article
Publishing year: 2025
Journal article
Energies, 2025, Volume 18, Issue 8
Scopus
Adoption of Waste Heat Recovery Technologies: Reviewing the Relevant Barriers and Recommendations on How to Overcome Them
Publishing year: 2022
Journal article
Operations Research Forum, 2022, Volume 3, Issue 1
Scopus
The wide adoption of heat recovery technologies in industry is hampered by specific “barriers” related to both technical and non-technical issues. This paper attempts to determine these barriers and make recommendations on how to address them. First, a literature review of related material is presented. Among numerous barriers, the main ones identified are (i) lack of information, (ii) lack of technology knowledge, (iii) technology risks, (iv) high initial and running and maintenance costs, (v) lack of financial support and lack of governmental incentives, (vi) size and available space limitations, (vii) lack of available infrastructure, (viii) production constraints and risk of production disruptions, (x) risk of the system negative impact on the company operations, and (xi) policy and regulations restrictions. Then, based on the above, a structured questionnaire on barriers to the adoption of waste heat recovery (WHR) technologies was prepared and issued to a number of industries throughout the European Union. Upon analyzing the questionnaire, an assessment of the importance and negative impact of each of the above-mentioned barriers is made. Subsequently, strategies and recommendations on how to overcome the barriers is reported. These recommendations are hoped to be adopted as far as possible in the packaging, installation, commissioning, and demonstration of new and old WHR technologies.
Waste Heat Recovery Technologies: Recommendations on how to Overcome Barriers to their Adoption
Publishing year: 2020
Conference paper
International Conference on Energy Sustainability and Climate Change, 2020
Repository
The fact that 30% of EU industry final energy is wasted through losses has led to the wide adoption of waste heat recovery (WHR) technologies. But their adoption is hindered by specific technical and non-technical “barriers”. An attempt is made here to determine such barriers and make recommendations on how to address them. This has been done through a literature review as well as on a review and discussions with people from related industry sectors. Moreover, a structured questionnaire on barriers to the adoption of WHR technologies has been issued to a number of industries across the EU. It turns out that the main barriers have been identified as: (i) lack of information, (ii) lack of technology knowledge, (iii) technology risks, (iv) high initial and running and maintenance costs, (v) lack of financial support and lack of governmental incentives, (vi) size and available space limitations, (vii) lack of available infrastructure, (viii) production constraints and risk of production disruptions, (x) risk of the system negative impact on the company operations, (xi) policy and regulations restrictions. Furthermore, an assessment of the importance and negative impact of each of the above-mentioned barriers is given based on the analysis of the questionnaire. Finally, based on the above, recommendations on how to overcome the barriers and a suggestion for related case study are presented, with the hope of their adoption, when possible, by stakeholders.
The potential of utilizing buildings' foundations as thermal energy storage (TES) units from solar plate collectors
Publishing year: 2020
Journal article
Energies, 2020, Volume 13, Issue 11
Repository
Underfloor heating systems provide comfort due to the natural heat flow distribution by a network of pipes, conventionally connected to a heat pump operating at low temperatures. To this extent, a renewable energy source could be an alternative solution. Acting as a case to investigate such systems, the Mediterranean island of Cyprus with a plethora of sunny days points to solar energy as the obvious solution. In this study, solar collector systems are recruited to supply the required heat for a typical Cypriot house, with the building's foundation acting as a thermal energy system (TES) unit. The heat supply to the building can then be distributed with natural convection from the TES. The solar collectors and the building's foundation system are studied with the aid of two software programs, namely TRNSYS and COMSOL Multiphysics. The former is used for the calculation of the heating and cooling load of the house as well as to estimate the energy provided by the flat plate solar collectors at specific conditions. The latter is then used to examine the TES unit with the heat gain/loss of the building. The obtained results, including analyses on the solar collectors' area and the foundation thickness indicate that the suggested system would be able to sufficiently cover, partially or fully, the building's heating load.
Residential Buildings’ Foundations as a Ground Heat Exchanger and Comparison among Different Types in a Moderate Climate Country
Publishing year: 2020
Journal article
Energies, 2020, Volume 13, Issue 23
Repository
Shallow Geothermal Energy Systems (SGESs) constitute Renewable Energy Systems (RES), which find application in the residential sector through the use of Ground Source Heat Pumps (GSHPs). GSHPs are associated with Ground Heat Exchangers (GHEs), whereby heat is gained/lost through a network of tubes into the ground. GSHPs have failed to flourish in the RES market due to their high initial costs and long payback periods. In this study, the use of Energy Geo-Structure (EGS) systems, namely, the foundation (or energy) piles and the foundation bed of a residential building in Cyprus, was computationally modeled in the COMSOL Multiphysics software. First, the single-houses’ trend in number of units and area in Cyprus was examined and a theoretically typical house with nearly Zero Energy Building (nZEB) characteristics was considered. The heating and cooling loads were estimated in the TRNSYS software environment and used as inputs to investigate the performance of the GSHP/GHE systems. Both systems were shown to exhibit steady performance and high Coefficient of Performance (COP) values, making them an alternative RES solution for residential building integration. Next, the systems were economically evaluated through a comparison with a convectional Air Source Heat Pump (ASHP) system. The economic analysis showed that the cost of the suggested conversions of the foundation elements into GHEs had short payback periods. Consequently, either using the foundation piles or bed as a GHE i...
49
Unique publications
20.4%
Open access (10 publications; 27 without information)
28.6%
With other institutions (14 publications; 28 without information)
H-Index Reports
| Index type | Scopus | Google Scholar | Web of Science |
|---|---|---|---|
| H-index | 14 | 15 | 1 |
| H5-index | 1 | 2 | 0 |
| H10-index | 7 | 7 | 0 |
Publications per year and source
No description yet.
- Faculty
- Faculty of Engineering and Technology
- Department
- Department of Mechanical Engineering and Materials Science and Engineering